Cinnamyl formate is a member of styrenes.
Definition
Cinnamyl formate is a member of styrenes.
Source: PubChem
US FDA substance register · UNII 896AGS89RD · registered name CINNAMYL FORMATE · single chemical substance
Cosmetic roles
Safety & regulatory references
Not classified under Korea’s toxic-substance GHS list · existing chemical substance
More data — names, identifiers, properties, test records, literature
Names & identifiers
- CAS No.chemical registry number
- 104-65-4
- EC No.EU chemical inventory number
- 203-223-3
- DTXSIDUS EPA chemical ID
- DTXSID00861714
- DTXCIDUS EPA compound ID
- DTXCID40810600
- IUPAC
- 3-Phenylprop-2-en-1-yl formate
- Molecular formula
- C10H10O2
- Molecular weight
- 162.188 g/mol
Measured properties
- Appearance
- Colourless to slightly yellow liquid, green, herbaceous, balsamic odour
- Boiling point
- 250 °C
- Solubility
- insoluble in water, soluble in oils · miscible (in ethanol)
- Density
- 1.075-1.082
- Melting/freezing point
- 0 ℃
- Initial boiling point and range
- 250 ℃
- Flash point
- 100 ℃((at 101325 Pa))
- Vapour pressure
- 2.666 ㎩ ((at 25 ° C))
- Water solubility
- 725.1 ( at 25°C water) ㎎/ℓ
- Vapour density
- &, gt, = 1.075 ~ 1.082g/cm³
- Relative density
- 1.082 (at 20° C)
- Viscosity
- 2.71 cP
- Molecular weight
- 162.188
Values measured on the substance itself. The KOSHA data are a reference for writing and reviewing safety data sheets, not a specification for a commercial raw material.
Source: PubChem · KOSHA safety data sheets (Korea)
What products actually use it for
What the 5 products reported to the US EPA with this ingredient use it for. Products outside cosmetics are included, so the top few rows are its main uses.
- Fragrance3
- Flavouring and nutrient2
Source: US EPA CompTox dashboard
Irritation and sensitisation studies
3 skin studies and 1 eye studies are on record.
The study conclusions largely agree (100%). These tests are on the raw material itself; irritation at the amount in a finished product is a different question.
See all 4 studies
- Not likely to be sensitizing
skin sensitisation · Screening · according to other guideline: as mentioned below - Not likely to be sensitizing
skin sensitisation: in vivo (non-LLNA) · Screening · according to other guideline: as mentioned below - Studies Indicate No Significant Irritation
skin irritation: in vivo · Screening · other guideline: as mentioned below according to - Studies Indicate No Significant Irritation
eye irritation: in vivo · Screening · other guideline: as mentioned below according to
Source: US EPA CompTox dashboard
Linked databases 12
- Australian Industrial Chemicals Inventory (AICIS)
- EU CosIng ingredient list 2
- Korea toxic substances GHS register (NIER)
- KOSHA safety data sheets (Korea)
- NIST Chemistry WebBook
- PubChem 2
- UniChem cross-reference IDs
- US EPA CompTox dashboard 2
- US EPA DSSTox chemical database
- US FDA substance registration (GSRS)
- US FDA Unique Ingredient Identifier (UNII)
- Wikidata