Gloshell
Ingredients

Ingredient Dictionary

GAMMA-METHYLDECALACTONE

5-Hexyldihydro-5-methyl-2(3H)-furanone is a gamma-lactone.

Molecular structure

Definition

5-Hexyldihydro-5-methyl-2(3H)-furanone is a gamma-lactone.

Source: PubChem

US FDA substance register · UNII ANJ13KO1RK · registered name .GAMMA.-METHYLDECALACTONE · single chemical substance

Source: US FDA Unique Ingredient Identifier (UNII)

Cosmetic roles

Gives the product a scentPERFUMING
More data — names, identifiers, properties, test records, literature

Names & identifiers

GAMMA-METHYLDECALACTONEINCI2(3H)-Furanone, 5-hexyldihydro-5-methyl-Synonym
CAS No.chemical registry number
7011-83-8
EC No.EU chemical inventory number
230-291-1
DTXSIDUS EPA chemical ID
DTXSID3041299
DTXCIDUS EPA compound ID
DTXCID1021299
IUPAC
5-Hexyl-5-methyloxolan-2-one
Molecular formula
C11H20O2
Molecular weight
184.279 g/mol

Measured properties

Appearance
Liquid · clear, colourless liquid with a jasmine odour
Boiling point
135.00 °C. @ 0.50 mm Hg · 135 °C (0.5 mm Hg)
Solubility
soluble in alcohol, insoluble in water · (in ethanol)
Density
0.930-0.950
Colour
colourless
Melting/freezing point
-14.2 ℃(1008hPa)
Initial boiling point and range
285 ℃(1013hPa)
Flash point
144 ℃(1013 hPa)
Vapour pressure
60 ㎩ (25°C)
Water solubility
419 ㎎/ℓ (20°C)
Vapour density
6.360890576458406
Relative density
0.943 (20°C)
n-Octanol/water partition coefficient (Kow)
2.8 (25 °C)
Auto-ignition temperature
360 ℃ (1 008.3 - 1 012.5 hPa)
Molecular weight
184.275

Values measured on the substance itself. The KOSHA data are a reference for writing and reviewing safety data sheets, not a specification for a commercial raw material.

Source: PubChem · KOSHA safety data sheets (Korea)

What products actually use it for

What the 7 products reported to the US EPA with this ingredient use it for. Products outside cosmetics are included, so the top few rows are its main uses.

  • Fragrance5
  • Flavouring and nutrient2

Source: US EPA CompTox dashboard

Irritation and sensitisation studies

3 skin studies and 1 eye studies are on record.

Classed as low3

The study conclusions largely agree (100%). These tests are on the raw material itself; irritation at the amount in a finished product is a different question.

See all 4 studies
  • Studies Indicate No Significant Irritation
    skin irritation: in vivo · Screening · other guideline: OECD 406 equivalent or similar to
  • Not likely to be sensitizing
    skin sensitisation: in vivo (non-LLNA) · Screening · equivalent or similar to OECD Guideline 406 (Skin Sensitisation)
  • Studies Indicate No Significant Irritation
    skin irritation: in vivo · Screening · OECD Guideline 404 (Acute Dermal Irritation / Corrosion) according to
  • Studies Indicate No Significant Irritation
    eye irritation: in vivo · Screening · OECD Guideline 405 (Acute Eye Irritation / Corrosion) according to

Source: US EPA CompTox dashboard

Linked databases 12